Fike fm 200 pdf files

This specification outlines the requirements for a crosszoned detection and total flooding fm 200 fire suppression system. In light of the covid19 pandemic, fike corporation is taking the following measures to protect our employees and business partners from the virus, limit the spread of the virus in our global communities, and continue to support your business with. Fm 200 hydroflourocarbon hfc hfc 125 fe25 hydroflourocarbon hfc. Things to consider when specifying clean agent systems. Concept fire suppressions hfc227ea clean chemical fire suppression agent is commonly called fm 200, a trade name from great lakes chemical corp. Why just contain a fire when you can extinguish it. Evax, fike, central, shield, mueller, giacomini, rb pumps, bombas, ideal pumps, joslyn pumps. The work described in the specification consists of all labor, materials, equipment, and. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. Fm 200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. Learn how the the fm200 clean agent fire protection system hfc227ea leaves no residue and doesnt require costly cleanup. Never give anything by mouth to an unconscious person. Fike clean agent containers with impulse valve must use an impulse releasing module irm to supervise the agent release circuit wiring for open and ground fault conditions from the container to the control panel.

When symptoms persist or in all cases of doubt seek medical advice. Fike s clean agent system with fm200 also known as hfc227ea, uses fike s patented rupture disc valve design offering additional flexibility, effectiveness and speed. Fm200 clean agent fire suppression system hfc227 fike. They are effective for total flooding protection against hazards involving liquid. Medical facilitiesups roomstelecommunication facilitiescomms roomsdata centres. Fm 200 may cause frostbite if liquid or escaping vapor contacts the skin. Product overview fm200 fire suppression system clean agent power protects people and property n nonconductive and will not shortout electronic equipment or thermally shock detects fire in early stages n suppresses class a, b and c fires n less visual obscuration and minimal risk to personnel n colorless, odorless clean agent leaves no residue n electrically. The atmospheric lifetime of fm 200 has been determined to be 36. Fm 200 is listed as an acceptable replacement for halon 1 and halon 1211 in the united states environmental protection agencys significant new alternatives policy snap program. Material safety data sheet fm200 fire extinguishing agent revision date. Fm200 fire suppression system 112 bs 336 male an introduction to naffco. Fire suppression system chemetron cylinder fm200 3d cad.

Firefighting measures suitable extinguishing media. The ansul fm 200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. First aid measures eyes immediately flood the eye with plenty of warm water for at least 15 minutes, holding the eye open. The work described in the specification consists of all labor, materials, equipment, and services necessary. Fike fm 200 clean agent fire suppression system with the shp pro control panel fm 200 system w shp pro specification page 2 of 8 pn. Fm 200 fire suppressant can be safely used where people are present.

Design, installation maintenance manualfm200fike gases. The clean agent is retained in the container by a impulse valve assembly which contains a fastacting rupture disc. Fm 200 is an important part of an environmentally responsible clean agent fire suppression solution with a zero ozonedepleting potential. Vision to eliminate catastrophic loss of life and assets for companies around the world. This type of fire suppression system is usually used in. Fire suppression system chemetron cylinder fm 200 fire. Conventional fire alarm and suppression system fike. Unlike traditional water sprinklers, each of fike s fastacting automatic fire suppression solutions are designed to extinguish fire hazards as quickly as possible, minimizing fire damage, smoke damage and even water damage. The fm 200 agent is stored in cylinders as a liquid and pressurized with nitrogen, saving huge amounts of storage space. Fm 200 may cause frostbitelike effects if the liquid or escaping vapors contact the eyes. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems. Fm 200 is a widely accepted replacement for halon 1. January, 2008 3 the installing contractor must have a minimum of five 5 years experience in the design, installation and testing of clean agent, or similar, fire suppression systems. Fire suppression system chemetron cylinder fm 200 fire suppression system chemetron cylinder fm 200 loading.

What is fm200 fire suppression and what are its advantages. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. The msds format adheres to the standards and regulatory. Gaseous fire suppression systems pressure relief vent. This manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. The ivo can be activated electrically via a signal from fike control panel or manually by depressing red strike buttom. That translates into minimal equipment facility damage and little or no business interruption. Mission fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and.

After an fm 200 system discharge, the fm 200 cylinders should be returned to an authorized. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Fm 200 total flooding fire suppression system general the fm 200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. In applications where space is at a premium, fm 200 fire suppression systems are the superior choice. Fm200 fire suppression system by fike bfpe international. Not applicable will not burn unsuitable extinguishing media.

Dupont also manufacture this agent under the trade name fe227 and both fire suppression systems are available from concept fire suppression ltd. Ecs clean agent fire suppression system kiddefenwal. Data sheet agent storage containers with hfc227ea description fike clean agent containers are used in fire extinguishing systems to store the clean agent until a fire develops and the agent must be released. A proven, effective and reliable fire suppression option. Fm 200 is an odorless, colorless, liquefied compressed gas. Design, installation maintenance manualfm200fike free download as pdf file. In one study, human volunteers were selected to inhale fm 200 at a concentration of 6000 ppm but the study was terminated due to a rise in pulse rate that was believed to. Fike s fm200 fire suppression system is a clean agent system with fike s impulse valve technology, which greatly improves the performance of clean agent fire suppression systems over mechanical valve systems by combining the reliability and efficiency of a rupture disc with the flexibility of electric. Fire extinguishing agent properties, uses, storage, and. Once the fm 200 fire suppression system discovers a fire in the room, the fm 200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from getting out of control. August 19, 20 fe125 ecaro125 ecaro made by dupont hydrofluorocarbon hfc first attempt for approval failed to pass toxicity. Fm 200 fire suppression system orr protection systems. This makes it a suitable choice for new installations using total flooding systems, and for halon 1 replacement applications.

Explaining the difference between a conventional and addressable fire alarm control panel. This experimental data is the basis of the new fire suppression systems association fssa guide to estimating pressure relief vent areas. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. It is a waterless fire protection system thats released into the risk inside a 10 second time frame. And it discharges in 10 seconds or less, extinguishing a fire. Ecs clean agent fire suppression systems are the preferred fire suppression solution for facilities that cannot afford the downtime associated with a fire or typical waterbased fire suppression systems. The fm 200 fire suppression system contains sensitive detectors that can detect even the smallest fires. In light of the covid19 pandemic, fike corporation is taking the following measures to protect our employees and business partners from the virus, limit the spread of the virus in our global communities, and continue to support your business with essential lifesafety products and services. Fire suppression systems fike fast solutions for any application. Fm 200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. Fm 200 is a suitable fire extinguishing agent for total flooding, portable, and local application systems. In light of the covid19 pandemic, fike corporation is taking the following measures to protect our employees and business partners from the virus.